User’s Manual Pulse • PulsePlus
51
CV Out Curve
Please note, that the scaling method is depending on the type of connected
synthesizer. When using the wrong setting, the adjustment described below can
not be proceeded correctly.
CV Out Adjust
CV Out Offset
To proceed the adjustment, connect the CV Out 1 output of the Pulse to the
CV input of the synthesizer. Connect the Gate jacks in the same way. What to
do next depends on the scaling method of the output signal, which is
controlled by the parameter CV Out Curve:
• On linear scaling, first set both CV Out Adjust and CV Out Offset to
0. Now change the spread via CV Out Offset until the synthesizer
plays a tempered scale. Then tune the absolute pitch via CV Out
Adjust.
• On logarithmic scaling, first adjust the spread via CV Out Adjust.
Then use CV Out Offset to fine tune the pitch.
The parameters of the CV/Gate interface can be transmitted as a seperate sysex dump.
By forcing an All Dump manually or via a Dump Request message, the CV/Gate
Interface Parameter Dump will be transmitted. The corresponding data format is
described in the appendix.
DC Offset for CV 1 Out and CV 2 Out.
-64...+63
Adjust parameter for the CV 1 Out output
(Spread).
-64...+63
Linear
(V/Hz):
Logarithmic
(1V/Octave):
Determines the scaling method of the CV 1
output.